Danyl Chip card reader interface CAPI 5
Version 5.1180.0000

Product compatibility

Compatible with the following PHAROS Versions:
Version 4.50 onwards

Release History


Build 1180
Changed: add the timeout for every command session, handle the "unknown message".
Build 1109
Set timeout longer to fit a new card.
Core library changes to support other card readers, no functional change.
Build 1021
Improve release process. No functional changes.
Build 5
Now support PHAROS station version 4.5 or great.
Build 4
Fixed error "Unable to set com state: 87" that appeared on some older PCs running NT 4.0.
Changed maximum balance from 99990 to 999990.
Build 1
Did not run under user-level permissions
Improved release process.

Testing information

Model Firmware Version Date Tested
P/5000Revision TS/AUX A4/D320 December 2000
P/5000TS/AUX A7/D308 March 2001

The Danyl Chip Card Reader Logon DLL supports the Danyl smart card reader. The DLL returns a card balance and four-digit Site Code for tracking, but no individual ID. The DLL cannot tell the difference between cash cards and unit cards.

 

The Danyl smart card reader must have the AUX (i.e. serial) interface option.

Card Reader Wiring

This diagram views the card reader connector from the rear.

Wiring specifications previous to build X.XX.0003 caused intermittent failure of the Danyl Chip Logon DLL. The Card Reader ground (Pin 6) was connected to the PC’s RTS line (Pin 7). New wiring specification corrects the problem but the DanylChip.dll is compatible with both previous and new cable wiring specifications.

 

Card Reader             PC
8 pin din                    9 pin serial
2 Tx                             - 2  Rx
3 Rx                             - 3  Tx
4 Status                        - 6  DSR
5 Control                      - 4  DTR
6 GND                         - 5  GND

 